Telephone Building Entrance Station Protection

1360 Series

Model 1360 Asymmetrical Operation
Model 1360B Balanced Operation

Circa 1360>
</center>
<br>
Replaces Reltec R356T and Siecor SPD CT5200N24

<h3>Description:</h3>
<p align=The models 1360 and 1360B are designed to provide superior transient and power fault protection for most standard station protection applications. The characteristics of the solid state protector are far superior to gas tube technology in speed of response to faults and are virtually immune to overshoot, aging, and repeated tripping within rated limits. The balanced configuration (model 1360B) provides the best protection against line to line metallic surges where the transient on one side slightly lags the other. A surge on either side of the line will cause both sides of the device to fire providing simultaneous grounding. Nominal breakdown voltage for both devices is 300VDC.

All station protectors come with an external fail-safe mechanism that ensures safe operation even under the most adverse conditions. Under continuous surge conditions, the device will short both sides of the circuit to ground.

Application:

The models 1360 and 1360B station protectors are well suited to single or dual pair applications in residences and other low pair count customer premise installations where superior transient protection is desired. Industry standard design allows installation into most standard Network Interface Devices.

Features & Benefits

bulletSolid state technology provides nanosecond response time
bulletLonger life span than conventional gas tube
bulletBalanced operation (1360B)
bulletUL listed
bulletReduced "let through" of dangerous transients
bulletReduced number of service calls and carbon arrestors
bulletPrevents damage by "lagging" or sneak transients
bulletUL listed Documented safe performance

Dimensions

1.2"H x 2.25"W x 1.5"D

SPECIFICATIONS

 
 

  1360

  1360B

 

  1360

  1360B

  DC Breakdown (nominal)

   

Capacitance

   
 @100V/µsec

 300V

300V

1Vrms@1KHZ, 50VDC

<100pf

<100pf

           

  Peak Pulse Current (max)1

   

  Insulation Resistance

   

 @ 8x20 µsec

250A

250A

@50VDC

>100M ohms

>100M ohms

@10x 160 µsec

150A

150A

     

@10 x 1000 µsec

100A

100A

Fail- safe Operation

 

 
     

@1.0 A

<50 sec

<50 sec

  Holding Current

 200(min)

<200(min)

 @5.0 A

<15 sec

<15 sec

     

@20 A

>10 sec

>10 sec

Surge life
(min operations)2

   

@60 A

<3 sec

<3 sec

@10A, 10 x 1000 µsec

unlimited

unlimited

     

@100A, 10 x 1000 µsec

>300

>300

  Balanced Operation

No

Yes

@1Arms, 1 sec

>60

>60

     

@10 Arms, 1 sec

>20

>20

     

1total surge rating is 2x listed with respect to ground during a simultaneous surge
2service life requirement as per Bellcore TR-NWT-000974