Balanced Operation - Heavy Duty with self-Resetting Current Limiters
Description:
The C3B1E-BAL and C4B1E-PTC/BAL premium series of 5 pin, 3 element protector modules are designed to provide superior transient and power fault protection for most standard telephone line applications. The common chamber, 3 electrode gas tube provides true
balanced operation. An over voltage on either side of the circuit enables the entire tube to ionize which provides a simultaneous path to ground for both sides of the circuit. This grounding prevents a second arriving transient on the opposite side to pass through to the
equipment. Nominal breakdown voltage for the 3B1E/4B1E series is 350VDC.
|
ORDERING INFORMATION
Model No. |
Order No. |
Pin1 |
Color |
C3B1E |
75001 |
Gold |
Black |
C3B3E |
75002 |
Gold |
Red |
C4B1E |
75003 |
Gold |
Black |
C4B3E |
75004 |
Gold |
Red |
SPECIFICATIONS
|
CT3BIE
|
|
CT3B1E |
DC Breakdown (nominal) |
|
Capacitance |
|
@100V/µsec |
350V |
1Vrms@1KHZ, 50VDC |
<1pf |
|
|
|
|
Impulse Breakdown Voltage |
|
Insulation Resistance |
|
@ 100V/µsec |
700A |
@50VDC |
>100M ohms |
@1KV/µsec |
150A |
|
|
|
|
Fail-
safe
Operation |
|
DC Holdover Voltage |
135V |
@1.0 A |
<50 sec |
|
<150rms |
@5.0 A |
<15 sec |
Surge life
(min operations) |
|
@20 A |
<10 sec |
@10A, 10 x 1000 µsec |
>3000 |
@60 A |
<3 sec |
@100A, 10 x 1000 µsec |
>300 |
|
|
10kA, 8 x 20 µsec |
10 |
Current Limiting (-PTC) |
|
@20kA, 8 x 20 µsec |
1 |
Hold current (ma) @20C= |
145 |
@65Arms, 11 cycles, 130A total |
1 |
R min/Rmax ohms= |
3/6 |
@10 Arms, 1 sec |
10 |
|
|
1surge rating is 2x with respect to ground during a simultaneous surge
2service life requirement as per Bellcore TR-NWT-0001361
3pin alloy refers to tip and ring pins. Unless otherwise noted, all ground pins are tin
(These products were previously referred to as CT3B1E and CT4B1E.)