Polyphaser dc Type
Netguard - NX Series
RJ-45 Plug in Data Protector
The NETGARD or NX Series is a RJ45 plug in data
protection platform used to protect computers, or peripheral equipment
associated with popular data protocols such as DSL, POE, ISDN, 10/100BASET, and
E1/T1.
APPLICATION:
NX1-** - The NX1 is an RJ45 series
lightning protection device for UTP interfaces. This series protects in
differential mode only and serves signal voltage levels of up to 5V. The
maximum surge handling of the NX1 series is 100A, 10/1000µs as defined by
Bellcore 1089. The NX1 is suitable for DSL, ISDN, E1/T1, 10/100 BaseT
Ethernet
NX2-** - The NX2 series is designed to
provide protection for STP applications. Protection is accomplished in both
differential and common mode. All eight pins are protected line-to-line and
line-to-ground. The maximum surge current handling of this device is 100A,
10/1000µs as defined by Bellcore 1089. This unit is useful for 10/100 BaseT
and E1/T1 applications. These devices must be grounded for optimum
performance.
NX3-** - The NX3 is designed for
protection of E1/T1 applications. This device protects pins 1-2 & 4-5 in
both differential and common modes and is designed for STP (Shielded Twisted
Pair) applications. This three stage suppression circuit surge current
rating is defined as 300A, 10/1000 µs per Bellcore 1089 and 3kA, 8x20µs per
IEC 61000-4-5. External grounding is required for optimum performance.
NX4-** - The NX4-05 series is designed
for STP (Shielded Twisted Pair) applications. This device protects in both differential
and common line-to-line and line-to-ground modes. Each of the eight lines is
protected with a three stage suppression circuit. The surge current rating
of this device is 300A, 10/1000µs per Bellcore 1089 and 3kA, 8x20µs per IEC
61000-4-5. This device is useful in protecting 10/100BaseT, ISDN, DSL,
E1/T1, ADSL, POE, and DDS applications. External grounding is required for
optimum performance.
NX4-**-IG - The performance of the
NX4-**-IG is identical to that of the The NX4-05 & NX4-60 series except
the IG design provides internal electrical and surge isolation between
shield and ground. The NX4-**-IG is designed for STP (Shielded Twisted Pair)
applications. This device protects in both differential and common
line-to-line and line-to-ground modes. Each of the eight lines is protected
with a three stage suppression circuit. The surge current rating of this
device is 300A, 10/1000µs per Bellcore 1089 and 3kA, 8x20µs per IEC
61000-4-5. This device is useful in protecting 10/100BaseT, ISDN, DSL,
E1/T1, ADSL, POE, and DDS applications. External grounding is required for
optimum performance.
SPECIFICATIONS:
For complete specifications and drawings,
please click individual part number below.
|
|
|
|
|
CAT5/6,10/100BT,ISDN,DSL
|
All 8, L-L
|
+/- 12
|
|
CAT5/6,10/100BT,ISDL,DSL
|
All 8, L-L
|
+/- 70
|
|
CAT5/6,10/100BT
|
All 8, L-L
|
+/- 12
|
|
CAT5/6,10/100BT,ISDL,DSL
|
All 8, L-L
|
+/- 70
|
|
E1/T1
|
1, 2, 4, 5, L-L, & L-G
|
+/- 12
|
|
POE,ISDN,DDS,DSL,ADSL,10/100BT,CAT5/6
|
All 8, L-L & L-G
|
+/- 12
|
|
POE,ISDN,DDS,DSL,ADSL,10/100BT,CAT5/6,ISOLATED
GROUND
|
All 8, L-L & L-G
|
+/- 12 and +/- 100
|
|
POE,ISDN,DDS,DSL,ADSL,10/100BT,CAT5/6
|
All 8, L-L & L-G
|
+/- 70
|
|
POE,ISDN,DDS,DSL,ADSL,10/100BT,CAT5/6,ISOLATED
GROUND
|
All 8, L-L & L-G
|
+/- 70 and +/- 170
|
|